Power & Cooling
Energy infrastructure and precision cooling designed for uninterrupted service.
Power & Cooling
99.99%+ energy continuity with an independent medium voltage line from the grid, redundant UPS, and generator system.
⚡ Medium Voltage Power Line
Independent from the city grid, electrical energy transmitted to the data center via underground cables from the medium voltage power line reaches UPSs through unshared and physically protected transformers.
🔋Redundant UPS System
In the UPS system designed as N+1 more than the capacity requirement, the load is transferred uninterruptedly in case of any UPS failure. Completely independent A-B energy opportunity is provided upon request.
🛢️ Redundant Diesel Generator
In cases where grid energy is cut off, redundant diesel generators located in the specially ventilated underground floor come into play. The redundant system runs the generators in order during long interruptions to prevent possible failures.
❄️ N+1 Precision Cooling
Temperature and humidity are kept within a constant range with a precision air conditioning system throughout the data center area. With N+1 redundancy, cooling is provided uninterruptedly even during maintenance periods.
🔥 Gas Fire Extinguishing
In case of a fire that may occur in the data center, the FM-200 gas fire extinguishing system comes into play and extinguishes the fire within seconds without any damage to the internal hardware.
🌡️ Continuous Environment Monitoring
Smoke, gas, and temperature detectors placed throughout the building monitor the infrastructure in real-time. In case of abnormal conditions, the 24/7 automatic alarm system is activated.
Physical Security
Multi-layer access control and 24/7 camera monitoring system in compliance with ISO 27001 standards.
CCTV System
Security cameras are placed at every point of the building and all images are recorded. NOC, data center, and office sections are monitored separately.
Magnetic Card Access
Entries and exits are provided with magnetic security cards according to ISO 27001 standards. Unauthorized entries and exits are prevented, and all movements are kept under record.
Multi-Layer Zoning
Entry welcome, NOC, data center, and office areas are divided into independent security zones. Access authorization to each zone is managed independently.
ISO 27001 Compliance
Physical security procedures and access records are managed in accordance with the ISO 27001 information security standard. Compliance is constantly ensured through regular audits.